LogoLogo
English
English
  • General
    • About this documentation
    • What's new
      • 2025.1
        • 2025.1 U3
        • 2025.1 U2
        • 2025.1 U1
      • 2024.5
        • 2024.5 U1
      • 2024.4
      • 2024.3
  • Products
    • BERNARD Mobility Analyser (BMA)
      • Scope of delivery
      • Data sheet
      • Mounting
    • Mobile BERNARD Mobility Analyser (BMA)
      • Scope of delivery
      • Data sheet
      • Installation
      • Charge battery box
    • BERNARD Character Analyser (BCA)
      • Scope of delivery
      • Datasheet
      • Installation
        • Alignment of the BCA
    • BERNARD Mobility Controller (BMC)
      • Data sheet V2.2
      • Operating instructions V2.2
    • B101 & B401
      • Scope of delivery
      • Data sheet
      • Installation
  • Solution areas
    • Traffic survey
      • Traffic counting
      • Turning movement counting
      • Traffic Flow
    • Adaptive traffic control
    • Parking
      • Barrier-free parking
      • Single space parking
  • Control Center
    • Devices
      • Configuration
        • Object classes
      • Device health
      • Schedule
      • Device monitoring
    • Administration
      • Monitoring alerts
      • License management
      • Device update
      • User management
    • Control center API
      • Data analytics API
  • Data Center
    • Counting
      • Configuration of the survey
      • Data analysis
    • Traffic Flow
      • Configuration of a Traffic Flow survey
      • Data analysis
    • Data Center API
  • Bernard Technologies GmbH
    • Support Center
    • Terms and Conditions
Powered by GitBook
On this page
Export as PDF
  1. Products
  2. BERNARD Mobility Controller (BMC)

Data sheet V2.2

Rev. 06/2024

Technical data

Function

Interface between BMA and control unit of the traffic light system. Power supply of the connected BMA.

Number of BMAs

1 - 4

Outputs

12 potential-free (galvanically isolated) switches with screw connection. Imax = 700 mA, Umax = 60 VDC

Diagnostic outputs

Freely configurable, up to 4 potential-free (galvanically isolated) switches with screw connection. Imax = 700 mA, Umax = 60 VDC

Mounting

DIN rail

Connection cable BMA

2 cores, cable cross-section ≥ 0.75 mm² (AWG18), connection length up to 120 m at 30 V input voltage

Connection parameters

Input voltage

24 - 30 VDC

Power consumption

≤ 2 W for BMC plus ≤ 25 W per connected BMA

Environmental requirements

Temperature range

-20 °C to +60 °C

Humidity

≤ 95 % (at 25 °C)

Safety requirements

CE tested according to

EMC 2014/30/EU Road traffic signal systems - Electromagnetic compatibility EN 50293

Conducted interference emission and interference radiation

Compliant with EN55032 (CISPR32) Class B

Dimensions

height x width x depth

60 x 107(214) x 90 mm

Weight

< 1 kg

The supplier assumes no liability for compliance with local requirements or additional certifications that may be required in certain regions or markets. It is the responsibility of the purchaser or user to ensure that the product complies with local regulations and specific requirements that may go beyond the specified certifications. The supplier disclaims all liability for any damage or loss that may result from non-compliance with such additional requirements.