LogoLogo
English
English
  • General
    • About this documentation
    • What's new
      • 2025.1
        • 2025.1 U3
        • 2025.1 U2
        • 2025.1 U1
      • 2024.5
        • 2024.5 U1
      • 2024.4
      • 2024.3
  • Products
    • BERNARD Mobility Analyser (BMA)
      • Scope of delivery
      • Data sheet
      • Mounting
    • Mobile BERNARD Mobility Analyser (BMA)
      • Scope of delivery
      • Data sheet
      • Installation
      • Charge battery box
    • BERNARD Character Analyser (BCA)
      • Scope of delivery
      • Datasheet
      • Installation
        • Alignment of the BCA
    • BERNARD Mobility Controller (BMC)
      • Data sheet V2.2
      • Operating instructions V2.2
    • B101 & B401
      • Scope of delivery
      • Data sheet
      • Installation
  • Solution areas
    • Traffic survey
      • Traffic counting
      • Turning movement counting
      • Traffic Flow
    • Adaptive traffic control
    • Parking
      • Barrier-free parking
      • Single space parking
  • Control Center
    • Devices
      • Configuration
        • Object classes
      • Device health
      • Schedule
      • Device monitoring
    • Administration
      • Monitoring alerts
      • License management
      • Device update
      • User management
    • Control center API
      • Data analytics API
  • Data Center
    • Counting
      • Configuration of the survey
      • Data analysis
    • Traffic Flow
      • Configuration of a Traffic Flow survey
      • Data analysis
    • Data Center API
  • Bernard Technologies GmbH
    • Support Center
    • Terms and Conditions
Powered by GitBook
On this page
  • 1. mounting the camera
  • 2. Drilling of a second hole
  • Pole-mounted battery (optional)
  • 1. Positioning the battery
  • 2. Connecting the battery
  • Technical data of battery
  • Requirements for poles
Export as PDF
  1. Products
  2. BERNARD Mobility Analyser (BMA)

Mounting

Mounting process on a light pole

PreviousData sheetNextMobile BERNARD Mobility Analyser (BMA)

Last updated 9 months ago

1. mounting the camera

The camera is attached to the pole by using clamps. These adapt to the diameter of the pole.

2. Drilling of a second hole

A hole is drilled underneath the camera, where the cable gland with seal is then screwed in place. The cable is fed through the pole to the ground at this point. At the other end of the cable is the appropriate plug (2 or 3-pin) for the BMA

Pole-mounted battery (optional)

1. Positioning the battery

There is a cover in the lower section of the light pole. This can be opened with a special key to get the battery inside the pole. The power supply with plug or terminal strip should also be located here.

2. Connecting the battery

There is a two-pin plug on the battery that is used to charge the battery and a two-pin cable that is used to power the camera. If a terminal strip is available instead of a connector strip, the connector can be disconnected and the cables can be clamped directly into the terminal strip.

Technical data of battery

Input voltage
230 V AC with integrated charge controller

Output voltage

12 V DC

Energy reserve

18 h

Maximum power

21 W

Capacity

380 Wh

L x W x H

790 mm x 80 mm x 62 mm

Connections

for the camera: 3-pin connection for the power supply type F plug

Requirements for poles

Diameter min. 10 cm

Mounting the camera
Drilling of a second hole
Positioning the battery
Battery connections