Skip to content

Data sheet V2.2

Technical data
Function Interface between the BMA TLC and the traffic light controller; supplies power to the connected BMA TLCs.
Number of BMAs 1 - 4
Outputs 12 potential-free (galvanically isolated) switches with screw connection. Imax = 700 mA, Umax = 60 VDC
Diagnostic outputs Freely configurable, up to 4 potential-free (galvanically isolated) switches with screw connection. Imax = 700 mA, Umax = 60 VDC
Mounting DIN rail
Connection cable BMA 2 cores, cable cross-section ≥ 0.75 mm² (AWG18), connection length up to 120 m at 30 V input voltage
Connection parameters
Input voltage 24 - 30 VDC
Power consumption ≤ 2 W for BMC plus ≤ 25 W per connected BMA
Environmental requirements
Temperature range -20 °C to +60 °C
Humidity ≤ 95 % (at 25 °C)
Safety requirements
CE tested according to EMC 2014/30/EU Road traffic signal systems - Electromagnetic compatibility EN 50293
Conducted interference emission and interference radiation Compliant with EN55032 (CISPR32) Class B
Dimensions
height x width x depth 60 x 107(214) x 90 mm
Weight < 1 kg

Note

The supplier assumes no liability for compliance with local requirements or additional certifications that may be required in certain regions or markets. It is the responsibility of the purchaser or user to ensure that the product complies with local regulations and specific requirements that may go beyond the specified certifications. The supplier disclaims all liability for any damage or loss that may result from non-compliance with such additional requirements.