2025.2
Licenseplate detection (ANPR)
Two-Line License Plates (New)
The license plate recognition system now supports two-line EU vehicle license plates, which are primarily used on motorcycles. This is an ideal enhancement for the solutions parking and traffic flow.
👉 Details on BCA datasheet.
Example: Two-Line License Plate
Single-Line License Plates (Improved)
The recognition accuracy for single-line license plates has been further optimized, encompassing both license plate recognition and the detection of country and region.
Example: Single-Line License Plate
ANPR Calibration
A new calibration function helps you achieve optimal results. It enables:
- Optimization of mounting and alignment
- Precise positioning of the crossing line
- Diagnosis of recognition quality
👉 Details on ANPR Calibration
Note
The license plate recognition is available for the products BCA, B101, and B401, and requires a device update.
Data Center
Speed Estimation
Speed data is used for the analysis and visualization of vehicle speeds for a selected turning movement. This turning movement must be configured accordingly to display speeds.
Temporal Progression
This module shows the temporal progression of estimated vehicle speeds for the following percentiles: 5%, 15%, 25%, 50% (Median), 75%, 85% (v85), 95%. This data can be filtered by time using the red slider at the bottom, and by class using the toolbar on the left.
Cumulative Distribution
This module shows the cumulative frequency of speeds over the observed period. Here, too, the data can be filtered by time and by class.
👉 For more information, please refer to the solution traffic counting.
Minor Improvements & Bug Fixes
- API Rate Limit: Each API token is now limited to 100 requests per minute.
- The Traffic Flow API documentation has been updated.
- Downloads could previously lead to corrupted Excel files. This has been resolved.
- Events generated by rules are now processed correctly.
Control Center
Simplified Configuration of Event Triggers
The configuration of trigger options has been simplified and can now be done directly in-place – without additional dialogues or navigation steps.
Minor Improvements & Bug Fixes
- A warning is now displayed for doubly assigned potential-free contacts (BMC or Quido).
- Rules with the conditions "starts with," "ends with," or with occupancy status "free" are now functioning as expected again.
BMA
The BMA is now also available in a 48V DC variant. This expansion offers you greater flexibility for integration into existing infrastructures and power supply concepts.
👉 Datasheet